Choose your language
English Italian French Arabic German Japanese Chinese
Home
Profile
Products
  Control Panels For Road
Construction Machinery
 
  DC Control Panel Meters for Plastic Machinery  
  Distribution Control Panel  
  Digital Instruments  
  Thyristor Drive  
  SCR Power Regulator  
  Auto Burners  
  Hitachi Drives  
  Brainchild (BTC)  
PaperLess Recorder
Temperature Controller
Electricity Meter
  Shinko  
Temperature Transmitter
  RKC  
Temperature Controller
  Autonics  
Temperature Controller
Temperature Indicator
Counter / Timer
Panel Meter
Encoder
Sensors
Feedback
Contact Us
Sitemap
For further information
please write to:
 
name itself a quality
 
 
Hitachi Drives | Hitachi AC Drives | SJ200 Series
 
 
 
Variable Frequency Drive
 
 
     
             
   L200 Series   L300P Series      SJ200 Series   SJ300 Series
             
Click here to download full brochures
General Specification

The compact choice with full vector control for demanding aplications
  • Capacity Range: 0.2 - 7.5 KW
  • Global Standards to CE, UL, c-UL, C-Tick and CSA
  • Internal RS485 Interface
  • Internal Brake Chopper
  • Sensorless Vector Control (SLV)
  • Motor - Autotuning
  • Integrated EMC - Filter
  • 200% Starting Torque
  • Built - in Potentiometer
  • PID Control
  • Automatic Voltage Regulation
  • Motor Thermistor Input
Click here to download full brochures
Standard Specification

Inverter SJ200 200V - SERIES 400V - SERIES
002 NFEF 004 NFEF 007 NFEF 015 NFEF 022 NFEF 004 HFEF 007 HFEF 015 HFEF 022 HFEF 040 HFEF 055 HFEF 075 HFEF
 Protective structure IP20
 Maximum motor size (4p)  in KW 0.2 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 4.0 5.5 7.5
 Input supply phase Single phase / Three phase Three phase
 Rated input voltage 200VAC-10% ~ 240VAC+5% 50/60Hz ±5% 380VAC-10%~460VAC+10% 50/60Hz±5%
 Rated output voltage Three phase 200~240VAC
(Corresponds to input voltage)
Three phase 380~460VAC
(Corresponds to input voltage)
 Rated output current in A 1.4 2.6 4.0 8.0 11.0 1.5 2.5 3.8 5.5 8.6 13.0 16.0
 Output frequency range 0.5~400Hz
 Frequency accuracy
  (at 25°C±10°C)
Digital command:±0.01% of maximum frequency
(Analogue command:±0.2% of maximum frequency)
 Frequency setting  resolution Digital setting: 0.01Hz Analogue setting: mixmum frequency / 1000
 Voltage / frequency  characteristic Intelligent Vector Control, Constant or reduced torque
 Overload current capacity 150% for 60 seconds (once every 10 munites)
 Acceleration /  deceleration  time 0.1~3600 s in selestable liner and non-liner mode
(second acceleration / deceleration usable)
 Starting torque (Using  SLV) 200% at 1 Hz
Breaking torque  
 Daynamic breaking,  feedback to capacitor
approx. 100% appr. 70% appr. 20%
approx. 100% appr. 70% approx. 20%
 External braking resistor
approx. 150% appr. 20%
approx. 100% approx. 20%
 DC injection breaking Breaking is on at the minimum frequency or less
(minimum frequency, breaking time and breaking force can be set)
Inputs  
 Frequ-  ency  setting  Digital
 operator
 External
 signals
Setting using keys   or portentiometer
0-10VDC (input impendance 10k Ohm) 4-20mA (input impendance 250 Ohm)
Potrntiometer 1k-2k Ohm, 1W
 Forward  /Reverse  run  Digital
 operator
 External
 signals
Via keys RUN (for start) and STOP/RESET (for stop)
(Default setting: foward run)
Intelligant input terminals configurable as FW and RV
 Intelligent input terminals  programmable as, ie. FW: Forward run start/stop RV: Revrse run start/stop CF1-CF4: Multistage speed
JG: jogging command AT: Anlogue current input selection 2CH: 2nd Accel./decel. time FRS:Free run stop EXT: External trip USP: USP function RS: Reset
SFT: Softwear lock PTC: Thermal protection DB: Ext. DB input SET: 2nd setting active UP: Acceleration (Remote) OWN: Decelerate (Remote)
   
 Outputs Intelligent output terminal programmable as, ie.
Frequency and current monitoring
FA1/FA2: Frequency arrival signal RUN: Motor running signal OL: Overload signal OD: Deviation signal at PID control AL: Alarm signal
0-10VDC, 8 bit
 Fault alarm contact On when the inverter trips (1 c contact). Alternatively usable as intelligent output terminal
 Other function Autouning, Automatic voltage regulation, retry; analogue gain/bias adjustment, frequency jump, upper/lower limiter, output frequency display, trip history monitoring, carrier frequency setting, PID control, automatic torque boost, USP function, 2nd setting function, ON/OFF control of cooling fan
 Protection functions Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault, overload, CT error, BRD error
 Environ-  ment Ambient temperature
Storage temperature and humidity
-10 ~ 50°C; > 40°C Current derating
-25 ~ 65°C
20 ~ 90% RH (no dew condersation)
 Options Remote operator, copy unit, cable for digital operator, reactor for improving power factor, noise fillter ProDrive Software
 Overall weight (approx.)  in  kg 0.7 0.8 1.3 2.3 2.8 1.3 1.7 2.8 5.5 5.7
 *200v/3Ph inverters for 3.7kw, 5.5 kw and 7.5 kw also available
TOP

 SJ200 Series Dimensions

Type SJ200 022 NFEF 004 NFEF 007 NFEF 015 NFEF 022 NFEF 004 HFEF 007 HFEF 015 HFEF 022 HFEF 040 HFEF 055 HFEF 075 HFEF
Widht mm 80 80 110 110 110 110 180
Hight mm 140 140 155 155 155 155 250
Depth mm 110 124 146 173 146 173 163

TOP

Click here to download full brochures